Design conditions

Material (Limited database)

Buy me a burger to unlock full material database.

Component geometry

ASME B31.3 branch tees

Factors/Tolerances

Welded Branch (Tees) (ASME B31.12 par. IP-3.4.2)

Design conditions

Project name

Design pressure

P = [MPa]

Design temperature

T = [°C]

Material

Name

Basic allowable stress

S = [MPa]

Component geometry

Pipe

Diameter

Dh = [mm]

Thickness

tnh = [mm]

Branch

Diameter

Db = [mm]

Thickness

tnb = [mm]

Reinforcement

Thickness

tr = [mm]

Width

wr = [mm]

Factors/Tolerances

Quality factor

E = [-]

Material performance factor

Mf = [-]

Mechanical allowances

c = [mm]

Manufacturer's thickness tolerance

Mill = [%]

Coefficient

Y = [-]

Condition (P/SE ≤ 0.385)

-

Wall thickness

Pipe

Minimum wall thickness

Th = [mm]

Pressure design thickness

th = [mm]

Branch

Minimum wall thickness

Tb = [mm]

Pressure design thickness

tb = [mm]

Nomenclature

The angle β between the pipe and branch is at least 45°

β = [deg.]

Effective length removed from pipe at branch

d1 = [mm]

Half width of reinforcement zone

d2 = [mm]

Height of reinforcement zone outside of run pipe

L4 = [mm]

Min. throat dim. of weld at branch periphery

Wb = tc = [mm]

Min. throat dim. of weld at outer edge of added reinforcement

Wo = [mm]

Results

Required reinforcement area

A1 = [mm2]

Reinforcement area in pipe wall

A2 = [mm2]

Reinforcement area in branch wall

A3 = [mm2]

Reinforcement area in added metal

A4r = [mm2]

Reinforcement area in welds

A4w = [mm2]

Total reinforcement area

A5 = [mm2]

Percentage area replacement

(A5 / A1).100% = [%]

-